{"product_id":"schichten-pufferspeicher-schoenberg-spsrr-1500-1388-l-2-waermetauscher","title":"Layered buffer tank Schönberg SPSRR 1500, 1,388 l, with 2 heat exchangers","description":"\u003cstyle\u003e .product-th{margin-top:2rem}.product-th h2{margin:0 0 1rem}.product-th__table{width:100%;border-collapse:separate;border-spacing:0}.product-th__table td{padding:.95rem 1rem;vertical-align:top}.product-th__label{font-weight:700;width:38%;color:#213670}.product-th__value{color:#1f2937}.product-th__table tr:nth-child(odd) td{background:#f4f7fb}.product-th__table tr:nth-child(even) td{background:#fafbfd} \u003c\/style\u003e \u003cdiv class=\"gema-section\"\u003e \u003ch2\u003eProduct Overview \u0026amp; Application Area\u003c\/h2\u003e \u003cp\u003eThe Schönberg SPSRR 1500 is a stratified buffer tank for heating water with two integrated heat exchangers. It is suitable for heating systems in which multiple heat generators, separate heat exchanger circuits, or different heat sources are to be integrated into a storage system.\u003c\/p\u003e \u003c\/div\u003e \u003cdiv class=\"gema-section\"\u003e \u003ch2\u003eTechnology \u0026amp; Equipment\u003c\/h2\u003e \u003cp\u003eThe stratification technology supports an orderly temperature distribution in the tank. The SPSRR 1500 features two integrated heat exchangers, each with a surface area of 3 m². For hydraulic connection, eight 1 1\/2\u0026quot; female threads are available for charging and discharging. Four 1\/2\u0026quot; female threads allow the integration of sensors and controllers.\u003c\/p\u003e \u003c\/div\u003e \u003cdiv class=\"gema-section\"\u003e \u003ch2\u003eEveryday Benefits\u003c\/h2\u003e \u003cp\u003eThanks to the two integrated heat exchangers, the tank can be used flexibly in systems with separate circuits. The multiple connection areas facilitate system-specific integration of charging and discharging, sensors, venting, and electric backup heating. The available insulation variants allow adaptation to installation dimensions, efficiency requirements, and installation conditions.\u003c\/p\u003e \u003c\/div\u003e \u003cdiv class=\"gema-section\"\u003e \u003ch2\u003eSystem Integration \u0026amp; Compatibility\u003c\/h2\u003e \u003cp\u003eThe SPSRR 1500 is intended for heating water and can be used in heating systems with wood heating, solar thermal systems, other heat generators, and, with proper hydraulic design, also as a buffer tank in heat pump heating systems. The integrated heat exchangers support separate circuits, while the direct tank connections are used for the hydraulic integration of the heating water circuit.\u003c\/p\u003e \u003c\/div\u003e \u003cdiv class=\"product-th\"\u003e \u003ch2\u003eTechnical Data at a Glance\u003c\/h2\u003e \u003ctable class=\"product-th__table\"\u003e \u003ctbody\u003e \u003ctr\u003e\n\u003ctd class=\"product-th__label\"\u003eModel\u003c\/td\u003e\n\u003ctd class=\"product-th__value\"\u003eSPSRR 1500\u003c\/td\u003e\n\u003c\/tr\u003e \u003ctr\u003e\n\u003ctd class=\"product-th__label\"\u003eStorage type\u003c\/td\u003e\n\u003ctd class=\"product-th__value\"\u003eStratified buffer tank\u003c\/td\u003e\n\u003c\/tr\u003e \u003ctr\u003e\n\u003ctd class=\"product-th__label\"\u003eNet capacity without heat exchanger\u003c\/td\u003e\n\u003ctd class=\"product-th__value\"\u003e1,388 l\u003c\/td\u003e\n\u003c\/tr\u003e \u003ctr\u003e\n\u003ctd class=\"product-th__label\"\u003eNumber of heat exchangers\u003c\/td\u003e\n\u003ctd class=\"product-th__value\"\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e \u003ctr\u003e\n\u003ctd class=\"product-th__label\"\u003eHeat exchanger surface area (top)\u003c\/td\u003e\n\u003ctd class=\"product-th__value\"\u003e3 m²\u003c\/td\u003e\n\u003c\/tr\u003e \u003ctr\u003e\n\u003ctd class=\"product-th__label\"\u003eHeat exchanger surface area (bottom)\u003c\/td\u003e\n\u003ctd class=\"product-th__value\"\u003e3 m²\u003c\/td\u003e\n\u003c\/tr\u003e \u003ctr\u003e\n\u003ctd class=\"product-th__label\"\u003eMax. operating pressure tank\u003c\/td\u003e\n\u003ctd class=\"product-th__value\"\u003e3 bar\u003c\/td\u003e\n\u003c\/tr\u003e \u003ctr\u003e\n\u003ctd class=\"product-th__label\"\u003eMax. operating pressure heat exchanger\u003c\/td\u003e\n\u003ctd class=\"product-th__value\"\u003e10 bar\u003c\/td\u003e\n\u003c\/tr\u003e \u003ctr\u003e\n\u003ctd class=\"product-th__label\"\u003eMax. operating temperature\u003c\/td\u003e\n\u003ctd class=\"product-th__value\"\u003e95 °C\u003c\/td\u003e\n\u003c\/tr\u003e \u003ctr\u003e\n\u003ctd class=\"product-th__label\"\u003eStorage tank material\u003c\/td\u003e\n\u003ctd class=\"product-th__value\"\u003eQuality steel S235JRG2\u003c\/td\u003e\n\u003c\/tr\u003e \u003ctr\u003e\n\u003ctd class=\"product-th__label\"\u003eDiameter without insulation\u003c\/td\u003e\n\u003ctd class=\"product-th__value\"\u003e1,000 mm\u003c\/td\u003e\n\u003c\/tr\u003e \u003ctr\u003e\n\u003ctd class=\"product-th__label\"\u003eHeight with insulation\u003c\/td\u003e\n\u003ctd class=\"product-th__value\"\u003e2,060 mm\u003c\/td\u003e\n\u003c\/tr\u003e \u003ctr\u003e\n\u003ctd class=\"product-th__label\"\u003eTipping dimension without insulation\u003c\/td\u003e\n\u003ctd class=\"product-th__value\"\u003e2,100 mm\u003c\/td\u003e\n\u003c\/tr\u003e \u003ctr\u003e\n\u003ctd class=\"product-th__label\"\u003eWeight without insulation\u003c\/td\u003e\n\u003ctd class=\"product-th__value\"\u003e300 kg\u003c\/td\u003e\n\u003c\/tr\u003e \u003ctr\u003e\n\u003ctd class=\"product-th__label\"\u003eLoading \/ unloading connections\u003c\/td\u003e\n\u003ctd class=\"product-th__value\"\u003e8 x 1 1\/2\u0026quot; female thread\u003c\/td\u003e\n\u003c\/tr\u003e \u003ctr\u003e\n\u003ctd class=\"product-th__label\"\u003eSensor \/ controller connections\u003c\/td\u003e\n\u003ctd class=\"product-th__value\"\u003e4 x 1\/2\u0026quot; female thread\u003c\/td\u003e\n\u003c\/tr\u003e \u003ctr\u003e\n\u003ctd class=\"product-th__label\"\u003eVentilation\u003c\/td\u003e\n\u003ctd class=\"product-th__value\"\u003e1 1\/4\u0026quot; female thread\u003c\/td\u003e\n\u003c\/tr\u003e \u003ctr\u003e\n\u003ctd class=\"product-th__label\"\u003eConnection for electric heating element\u003c\/td\u003e\n\u003ctd class=\"product-th__value\"\u003e2 x 1 1\/2\u0026quot; female thread, tank center and tank bottom\u003c\/td\u003e\n\u003c\/tr\u003e \u003ctr\u003e\n\u003ctd class=\"product-th__label\"\u003eInsulation variants\u003c\/td\u003e\n\u003ctd class=\"product-th__value\"\u003eEPS 100 mm, EPS 130 mm\u003c\/td\u003e\n\u003c\/tr\u003e \u003c\/tbody\u003e \u003c\/table\u003e \u003c\/div\u003e \u003cdiv class=\"gema-section\"\u003e \u003ch2\u003eInstallation\u003c\/h2\u003e \u003cp\u003eThe tank must be transported and installed standing upright, dry, and secured against tipping over. The installation location must be load-bearing, level, frost-free, and sufficiently accessible for connection, testing, and maintenance work. Hydraulic connection, pressure testing, and commissioning must be carried out by qualified personnel or a specialized company.\u003c\/p\u003e \u003c\/div\u003e \u003cdiv class=\"gema-section\"\u003e \u003ch2\u003eNotes\u003c\/h2\u003e \u003cp\u003eElectric heating cartridges may only be installed on the specifically designated red-marked connections. Before installation, the installation length, electrical data, fuse protection, and suitability of the heating cartridge must be checked separately. The insulation should only be installed after the unit has been set up, connection work has been completed, and a leak test has been performed.\u003c\/p\u003e \u003c\/div\u003e \u003cdiv class=\"gema-section\"\u003e \u003ch2\u003eScope of delivery\u003c\/h2\u003e \u003cul\u003e \u003cli\u003eSchönberg SPSRR 1500 stratified buffer tank\u003c\/li\u003e \u003cli\u003eInsulation depending on selected version\u003c\/li\u003e \u003c\/ul\u003e \u003c\/div\u003e","brand":"Schönberg","offers":[{"title":"100mm","offer_id":58216639693148,"sku":"SPSRR1500+EEKC","price":2123.54,"currency_code":"EUR","in_stock":true},{"title":"130mm","offer_id":58216639725916,"sku":"SPSRR1500+EEKB","price":2309.93,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0757\/7796\/6428\/files\/gema-shop-schichten-pufferspeicher-spsrr-1500_2f05201c-64b9-4f40-90d4-c47e142d1871.jpg?v=1783930945","url":"https:\/\/bg.gemashop.de\/en\/products\/sloyno-buferen-sd-za-shranenie-na-toplina-schonberg-spsrr-1500-1388-l-2-toploobmennika","provider":"GEMA Shop","version":"1.0","type":"link"}