{"product_id":"holzvergaserkessel-attack-slx-35-profi-35-kw","title":"Attack SLX 35 Profi wood gasification boiler 35 kW","description":"\u003cdiv class=\"gema-section\"\u003e \u003ch2\u003eProduct Overview \u0026amp; Application Area\u003c\/h2\u003e \u003cp\u003eThe Attack SLX 35 Pro wood gasification boiler is a log wood boiler for central hot water heating systems in single-family homes, larger residential buildings, holiday homes, and comparable properties. With a nominal output of 35 kW, it is suitable for systems where a powerful wood heating system with buffer tank operation is professionally planned and installed.\u003c\/p\u003e \u003cp\u003eThe boiler is designed for dry split logs and operates on the principle of wood gasification. The PROFI version uses electronic boiler control that manages operation based on boiler and flue gas temperature, thereby supporting controlled combustion in heating mode.\u003c\/p\u003e \u003c\/div\u003e \u003cdiv class=\"gema-section\"\u003e \u003ch2\u003eTechnology \u0026amp; Equipment\u003c\/h2\u003e \u003cp\u003eThe ATTACK SLX 35 Pro is designed as a wood gasification boiler with an induced draft fan. The boiler body is made of welded steel plate; wood gasification is prepared in the loading chamber, while combustion takes place in the downstream combustion chamber.\u003c\/p\u003e \u003cp\u003eIn the rear area, there is a tube heat exchanger with turbulators. These support heat transfer and facilitate regular cleaning of the heat exchanger. The PROFI control manages the induced draft fan and enables operation based on boiler and flue gas temperature.\u003c\/p\u003e \u003c\/div\u003e \u003cdiv class=\"gema-section\"\u003e \u003ch2\u003eEveryday Benefits\u003c\/h2\u003e \u003cp\u003eThe large loading chamber and the permissible log length make daily operation with split logs easier. By integrating a suitable buffer tank, the generated heat can be stored and released to the heating system as needed.\u003c\/p\u003e \u003cp\u003eThe technical design with return temperature boosting, buffer tank, and safety cooling circuit is designed for stable operation in the boiler room. Regular cleaning, suitable fuel, and professional adjustment remain crucial for reliable operation.\u003c\/p\u003e \u003c\/div\u003e \u003cdiv class=\"gema-section\"\u003e \u003ch2\u003eSystem Integration \u0026amp; Compatibility\u003c\/h2\u003e \u003cp\u003eThe Attack SLX 35 Profi is integrated into a hot water heating system and should be operated with a sufficiently sized buffer tank. For this performance class, a recommended buffer volume of 2,500 liters is specified.\u003c\/p\u003e \u003cp\u003eFor operation, suitable chimney draft, return temperature boosting to maintain the minimum return temperature, and the required safety devices must be taken into account. The specific design must always match the system, the building, and the heating load.\u003c\/p\u003e \u003c\/div\u003e \u003cstyle\u003e .product-th{margin-top:2rem}.product-th h2{margin:0 0 1rem}.product-th__table{width:100%;border-collapse:separate;border-spacing:0}.product-th__table td{padding:.95rem 1rem;vertical-align:top}.product-th__label{font-weight:700;width:38%;color:#213670}.product-th__value{color:#1f2937}.product-th__table tr:nth-child(odd) td{background:#f4f7fb}.product-th__table tr:nth-child(even) td{background:#fafbfd} \u003c\/style\u003e \u003cdiv class=\"product-th\"\u003e \u003ch2\u003eTechnical data at a glance\u003c\/h2\u003e \u003cp\u003eThe most important technical data of the ATTACK SLX 35 Profi at a glance.\u003c\/p\u003e \u003ctable class=\"product-th__table\"\u003e \u003ctbody\u003e \u003ctr\u003e \u003ctd class=\"product-th__label\"\u003eManufacturer\u003c\/td\u003e \u003ctd class=\"product-th__value\"\u003eAttack\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd class=\"product-th__label\"\u003eModel\u003c\/td\u003e \u003ctd class=\"product-th__value\"\u003eATTACK SLX 35 PROFI\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd class=\"product-th__label\"\u003eProduct type\u003c\/td\u003e \u003ctd class=\"product-th__value\"\u003eWood gasification boiler\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd class=\"product-th__label\"\u003eRated output\u003c\/td\u003e \u003ctd class=\"product-th__value\"\u003e35 kW\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd class=\"product-th__label\"\u003eFuel\u003c\/td\u003e \u003ctd class=\"product-th__value\"\u003eFirewood\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd class=\"product-th__label\"\u003eCombustion technology\u003c\/td\u003e \u003ctd class=\"product-th__value\"\u003eWood gasification\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd class=\"product-th__label\"\u003eEfficiency\u003c\/td\u003e \u003ctd class=\"product-th__value\"\u003e90.3%\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd class=\"product-th__label\"\u003eBoiler class\u003c\/td\u003e \u003ctd class=\"product-th__value\"\u003e5\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd class=\"product-th__label\"\u003eMaximum log length\u003c\/td\u003e \u003ctd class=\"product-th__value\"\u003e650 mm\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd class=\"product-th__label\"\u003eRecommended buffer tank volume\u003c\/td\u003e \u003ctd class=\"product-th__value\"\u003e2,500 l\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd class=\"product-th__label\"\u003eFlue pipe connection\u003c\/td\u003e \u003ctd class=\"product-th__value\"\u003e150 mm\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd class=\"product-th__label\"\u003eDraft requirement\u003c\/td\u003e \u003ctd class=\"product-th__value\"\u003e23 Pa\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd class=\"product-th__label\"\u003eMaximum operating pressure\u003c\/td\u003e \u003ctd class=\"product-th__value\"\u003e2.5 bar\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd class=\"product-th__label\"\u003eFlue gas temperature at rated output\u003c\/td\u003e \u003ctd class=\"product-th__value\"\u003e180 °C\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd class=\"product-th__label\"\u003eDimensions\u003c\/td\u003e \u003ctd class=\"product-th__value\"\u003e1,472 × 703 × 1,337 mm\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd class=\"product-th__label\"\u003eWeight\u003c\/td\u003e \u003ctd class=\"product-th__value\"\u003e570 kg\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd class=\"product-th__label\"\u003eElectrical connection\u003c\/td\u003e \u003ctd class=\"product-th__value\"\u003e230 V \/ 50 Hz \/ 10 A\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd class=\"product-th__label\"\u003ePower consumption at rated output\u003c\/td\u003e \u003ctd class=\"product-th__value\"\u003e42 W\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd class=\"product-th__label\"\u003eFlow \/ Return\u003c\/td\u003e \u003ctd class=\"product-th__value\"\u003eG 6\/4\u0026quot;\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd class=\"product-th__label\"\u003eSafety cooling circuit\u003c\/td\u003e \u003ctd class=\"product-th__value\"\u003eavailable\u003c\/td\u003e \u003c\/tr\u003e \u003c\/tbody\u003e \u003c\/table\u003e \u003c\/div\u003e \u003cdiv class=\"gema-section\"\u003e \u003ch2\u003eInstallation\u003c\/h2\u003e \u003cp\u003eThe installation of the wood gasification boiler must be carried out by a qualified person and must match the existing heating system, the chimney, and the buffer tank concept. For operation, a suitable chimney draft, return temperature control, and the prescribed safety devices must be taken into account.\u003c\/p\u003e \u003cp\u003eThe boiler is intended for installation in the boiler room. When integrating it, the requirements for the installation room, flue gas routing, heating water quality, return temperature, and electrical supply must be observed.\u003c\/p\u003e \u003c\/div\u003e \u003cdiv class=\"gema-section\"\u003e \u003ch2\u003eNotes\u003c\/h2\u003e \u003cp\u003eDry split logs are intended as fuel. For clean and stable operation, the wood should be sufficiently dry and match the permissible log length.\u003c\/p\u003e \u003cp\u003eThe boiler is not intended for installation in living spaces. Cleaning, maintenance, and operation should be carried out in accordance with the operating instructions to maintain combustion, heat transfer, and operational safety.\u003c\/p\u003e \u003c\/div\u003e \u003cdiv class=\"gema-section\"\u003e \u003ch2\u003eScope of delivery\u003c\/h2\u003e \u003cul\u003e \u003cli\u003eAttack SLX 35 Professional wood gasification boiler\u003c\/li\u003e \u003c\/ul\u003e \u003c\/div\u003e","brand":"Attack","offers":[{"title":"Заглавие по подразбиране","offer_id":49418334110044,"sku":"ASLXP35","price":3665.53,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0757\/7796\/6428\/files\/SLXprofi-webrender.webp?v=1774512395","url":"https:\/\/bg.gemashop.de\/en\/products\/holzvergaserkessel-attack-slx-35-profi-35-kw","provider":"GEMA Shop","version":"1.0","type":"link"}