{"product_id":"gema-mdc-plus-400-bundle-modul-heizstab-tehp75-7-5-kw-400-v","title":"GEMA MDC Plus 400 heating module + TEHP75 heating element 7.5 kW 400 V","description":"\u003cdiv class=\"gema-section\"\u003e \u003ch2\u003eProduct Overview \u0026amp; Application Area\u003c\/h2\u003e \u003cp\u003eThe GEMA MDC Plus 400 Bundle Module + Heating Rod TEHP75 7.5 kW 400 V combines a heating module for central heating systems with a matching electric heating cartridge for additional heat input into the heating circuit.\u003c\/p\u003e \u003cp\u003eThe bundle is suitable for systems where electric auxiliary heat, reheat, frost protection support, emergency heat support, or the use of surplus electricity from photovoltaic systems is planned. Proper hydraulic and electrical integration remains crucial.\u003c\/p\u003e \u003c\/div\u003e \u003cdiv class=\"gema-section\"\u003e \u003ch2\u003eTechnology \u0026amp; Equipment\u003c\/h2\u003e \u003cp\u003eThe MDC Plus 400 module provides the hydraulic integration into the heating circuit. It is designed as an electric flow-through heater or heating module for central heating systems and is integrated into the parallel heating circuit on the flow or return line of the main heat source.\u003c\/p\u003e \u003cp\u003eThe TEHP75 heating rod handles electric heat generation with 7.5 kW at 400 V. The electric heating cartridge features integrated insulation separation, a temperature controller, a safety temperature limiter, a protective cap with IP54 protection rating, and a sheath material made of Incoloy 825.\u003c\/p\u003e \u003c\/div\u003e \u003cdiv class=\"gema-section\"\u003e \u003ch2\u003eEveryday Benefits\u003c\/h2\u003e \u003cp\u003eThe bundle creates an additional electric heat source in the heating circuit and can support existing heat generators depending on the situation. This is particularly interesting when electrical energy is to be deliberately introduced as heat into the central heating system.\u003c\/p\u003e \u003cp\u003eThe combination of module and matching heating rod creates a clearly assignable system unit. This makes it transparent for operators which base module and which electric heating cartridge belong together.\u003c\/p\u003e \u003c\/div\u003e \u003cdiv class=\"gema-section\"\u003e \u003ch2\u003eSystem Integration \u0026amp; Compatibility\u003c\/h2\u003e \u003cp\u003eThe MDC Plus 400 module is intended for open or closed central heating systems with appropriate safety devices. The medium can be water or a glycol mixture suitable for heating systems up to a maximum concentration of 50%.\u003c\/p\u003e \u003cp\u003eOperation requires a functioning safety valve and an additional circulation pump. The circulation pump must ensure the necessary flow rate and be connected in parallel with the heating cartridge.\u003c\/p\u003e \u003c\/div\u003e \u003cstyle\u003e .product-th{margin-top:2rem}.product-th h2{margin:0 0 1rem}.product-th__table{width:100%;border-collapse:separate;border-spacing:0}.product-th__table td{padding:.95rem 1rem;vertical-align:top}.product-th__label{font-weight:700;width:38%;color:#213670}.product-th__value{color:#1f2937}.product-th__table tr:nth-child(odd) td{background:#f4f7fb}.product-th__table tr:nth-child(even) td{background:#fafbfd} \u003c\/style\u003e \u003cdiv class=\"product-th\"\u003e \u003ch2\u003eTechnical data at a glance\u003c\/h2\u003e \u003cp\u003eThe following information refers to the specific bundle consisting of the MDC module and the matching electric heating cartridge.\u003c\/p\u003e \u003ctable class=\"product-th__table\"\u003e \u003ctbody\u003e \u003ctr\u003e \u003ctd class=\"product-th__label\"\u003eNominal power\u003c\/td\u003e \u003ctd class=\"product-th__value\"\u003e7.5 kW\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd class=\"product-th__label\"\u003ePower consumption\u003c\/td\u003e \u003ctd class=\"product-th__value\"\u003e7,500 W\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd class=\"product-th__label\"\u003eVoltage\u003c\/td\u003e \u003ctd class=\"product-th__value\"\u003e400 V\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd class=\"product-th__label\"\u003ePhases\u003c\/td\u003e \u003ctd class=\"product-th__value\"\u003e3-phase\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd class=\"product-th__label\"\u003eConnection type\u003c\/td\u003e \u003ctd class=\"product-th__value\"\u003eDirect control, three-phase connection in star configuration\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd class=\"product-th__label\"\u003eHeating element connection size\u003c\/td\u003e \u003ctd class=\"product-th__value\"\u003eG 1 1\/2\u0026quot; \/ 6\/4\u0026quot;\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd class=\"product-th__label\"\u003eHeating element installation length\u003c\/td\u003e \u003ctd class=\"product-th__value\"\u003e650 mm\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd class=\"product-th__label\"\u003eUnheated zone\u003c\/td\u003e \u003ctd class=\"product-th__value\"\u003eapprox. 120 mm from sealing surface\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd class=\"product-th__label\"\u003eTemperature range\u003c\/td\u003e \u003ctd class=\"product-th__value\"\u003eapprox. 7-75 °C with frost protection range\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd class=\"product-th__label\"\u003eSafety temperature limiter\u003c\/td\u003e \u003ctd class=\"product-th__value\"\u003eapprox. 98 °C\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd class=\"product-th__label\"\u003eProtection rating of heating element\u003c\/td\u003e \u003ctd class=\"product-th__value\"\u003eIP54\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd class=\"product-th__label\"\u003eSheath material of heating element\u003c\/td\u003e \u003ctd class=\"product-th__value\"\u003eIncoloy 825\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd class=\"product-th__label\"\u003eHeating circuit connection module\u003c\/td\u003e \u003ctd class=\"product-th__value\"\u003eFemale thread G 1 1\/4\u0026quot;\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd class=\"product-th__label\"\u003eHeating cartridge connection module\u003c\/td\u003e \u003ctd class=\"product-th__value\"\u003eFemale thread G 1 1\/2\u0026quot;\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd class=\"product-th__label\"\u003eMDC module length\u003c\/td\u003e \u003ctd class=\"product-th__value\"\u003e850 mm\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd class=\"product-th__label\"\u003eMDC module insulation\u003c\/td\u003e \u003ctd class=\"product-th__value\"\u003e50 mm polyurethane foam\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd class=\"product-th__label\"\u003eMedium\u003c\/td\u003e \u003ctd class=\"product-th__value\"\u003eWater or suitable glycol mixture up to max. 50% concentration\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd class=\"product-th__label\"\u003eMax. operating pressure\u003c\/td\u003e \u003ctd class=\"product-th__value\"\u003e10 bar \/ 1.0 MPa\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd class=\"product-th__label\"\u003eMax. module operating temperature\u003c\/td\u003e \u003ctd class=\"product-th__value\"\u003e90 °C\u003c\/td\u003e \u003c\/tr\u003e \u003c\/tbody\u003e \u003c\/table\u003e \u003c\/div\u003e \u003cdiv class=\"gema-section\"\u003e \u003ch2\u003eInstallation\u003c\/h2\u003e \u003cp\u003eThe heating module is integrated into a parallel heating circuit on the flow or return line of the main heat source. Pipe routing, filling, venting, safety valve, and additional circulation pump must match the system and be carried out professionally.\u003c\/p\u003e \u003cp\u003eThe TEHP75 heating element is installed in a suitable socket G 1 1\/2\u0026quot; \/ 6\/4\u0026quot;. Installation, electrical design, protection, safety measures, and connection may only be carried out by qualified professionals.\u003c\/p\u003e \u003c\/div\u003e \u003cdiv class=\"gema-section\"\u003e \u003ch2\u003eNotes\u003c\/h2\u003e \u003cp\u003eOperation without sufficient water filling is not permitted. Before switching on, the module, heating circuit, and heating element must be completely filled and vented.\u003c\/p\u003e \u003cp\u003eNo shut-off valves may be installed between the safety valve and the device. The housing of the heating cartridge must not be covered or thermally insulated. The product information does not replace professional system planning, heat load calculation, or electrical sizing.\u003c\/p\u003e \u003c\/div\u003e \u003cdiv class=\"gema-section\"\u003e \u003ch2\u003eScope of delivery\u003c\/h2\u003e \u003cul\u003e \u003cli\u003eMDC Plus 400 module\u003c\/li\u003e \u003cli\u003eTEHP75 \/ WPI-7.5 electric heating element 7.5 kW, 400 V\u003c\/li\u003e \u003c\/ul\u003e \u003c\/div\u003e","brand":"Gema GmbH","offers":[{"title":"Заглавие по подразбиране","offer_id":58079630950748,"sku":"MDC400P+TEHP75","price":334.07,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0757\/7796\/6428\/files\/durchlauferhitzer-notheizung-mdc-400p-inkl-elektroheizstab-9-kw-4897799.webp?v=1770692302","url":"https:\/\/bg.gemashop.de\/en\/products\/gema-mdc-plus-400-bundle-module-heating-element-tehp75-7-5-kw-400-v","provider":"GEMA Shop","version":"1.0","type":"link"}