{"product_id":"gema-anschlusspaket-mdc-module-wita-umwaelzpumpe","title":"GEMA connection kit for MDC modules with WITA circulation pump","description":"\u003cdiv class=\"gema-section\"\u003e \u003ch2\u003eProduct Overview \u0026amp; Application Range\u003c\/h2\u003e \u003cp\u003eThe GEMA connection package for MDC modules is a coordinated connection and mounting set for the hydraulic integration of a GEMA MDC heating module into a suitable heating system. The package contains the fittings, connectors, mounting hardware, and a high-efficiency circulation pump required for a typical installation.\u003c\/p\u003e \u003cp\u003eThe connection package is suitable for all GEMA MDC modules. It is not intended as a standalone heat generator, but as system accessories for connecting, isolating, circulating, venting, filling, and pressure protection of the heating module connection.\u003c\/p\u003e \u003c\/div\u003e \u003cdiv class=\"gema-section\"\u003e \u003ch2\u003eTechnology \u0026amp; Equipment\u003c\/h2\u003e \u003cp\u003eThe package includes a WITA go.future WGF45625 high-efficiency pump with a 180 mm installation length. The pump supports the circulation of heating water in the heating module circuit and features electronic control options with constant curves, constant pressure curves, and proportional pressure curves.\u003c\/p\u003e \u003cp\u003eThe connection assembly includes, among other things, ball valves, a KFE drain valve, a check valve, an automatic air vent, a safety valve, as well as several malleable cast iron fittings and reducers. This allows the most important functional areas of the heating module connection to be set up in a structured pipe group.\u003c\/p\u003e \u003c\/div\u003e \u003cdiv class=\"gema-section\"\u003e \u003ch2\u003eEveryday Benefits\u003c\/h2\u003e \u003cp\u003eThe connection package facilitates the professional integration of the MDC heating module because the essential connection components are already assembled as a package. Shut-off, filling, venting, and backflow prevention can thus be clearly integrated into the system section.\u003c\/p\u003e \u003cp\u003eFor maintenance and service, the included ball valves and the KFE drain valve are particularly practical, as system sections can be shut off, filled, or drained in a controlled manner. The automatic air vent also supports operation by reducing air accumulation in the system.\u003c\/p\u003e \u003c\/div\u003e \u003cdiv class=\"gema-section\"\u003e \u003ch2\u003eSystem Integration \u0026amp; Compatibility\u003c\/h2\u003e \u003cp\u003eThe GEMA connection kit is intended for the hydraulic connection of GEMA MDC modules. The final integration must match the existing system hydraulics, the operating pressure, the pressure maintenance, the safety valve discharge line, and the electrical supply of the pump.\u003c\/p\u003e \u003cp\u003eInstallation, electrical connection, and commissioning should be carried out by qualified specialist personnel. The specific system design, the technical specifications of the connected components, and the nameplate of the supplied pump are decisive.\u003c\/p\u003e \u003c\/div\u003e \u003cstyle\u003e .product-th{margin-top:2rem}.product-th h2{margin:0 0 1rem}.product-th__table{width:100%;border-collapse:separate;border-spacing:0}.product-th__table td{padding:.95rem 1rem;vertical-align:top}.product-th__label{font-weight:700;width:38%;color:#213670}.product-th__value{color:#1f2937}.product-th__table tr:nth-child(odd) td{background:#f4f7fb}.product-th__table tr:nth-child(even) td{background:#fafbfd} \u003c\/style\u003e \u003cdiv class=\"product-th\"\u003e \u003ch2\u003eTechnical data at a glance\u003c\/h2\u003e \u003cp\u003eThe following information refers to the connection kit and the WITA circulation pump included in the kit.\u003c\/p\u003e \u003ctable class=\"product-th__table\"\u003e \u003ctbody\u003e \u003ctr\u003e \u003ctd class=\"product-th__label\"\u003eItem number \/ SKU\u003c\/td\u003e \u003ctd class=\"product-th__value\"\u003eMDCKAP\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd class=\"product-th__label\"\u003eVoltage\u003c\/td\u003e \u003ctd class=\"product-th__value\"\u003e230 V\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd class=\"product-th__label\"\u003eFrequency\u003c\/td\u003e \u003ctd class=\"product-th__value\"\u003e50 Hz\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd class=\"product-th__label\"\u003ePower consumption\u003c\/td\u003e \u003ctd class=\"product-th__value\"\u003e3 to 41 W\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd class=\"product-th__label\"\u003eConnection type\u003c\/td\u003e \u003ctd class=\"product-th__value\"\u003ePump thread 1 1\/2\u0026quot;, pipe connection DN 25 \/ approx. 1\u0026quot;\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd class=\"product-th__label\"\u003eMax. pressure\u003c\/td\u003e \u003ctd class=\"product-th__value\"\u003e10 bar pump system pressure; safety valve 3 bar included in the package\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd class=\"product-th__label\"\u003eMax. temperature\u003c\/td\u003e \u003ctd class=\"product-th__value\"\u003eMedia temperature +5 °C to +110 °C\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd class=\"product-th__label\"\u003eMaterial\u003c\/td\u003e \u003ctd class=\"product-th__value\"\u003eMalleable cast iron fittings, galvanized mounting material and valves as per scope of delivery\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd class=\"product-th__label\"\u003eElectronic control\u003c\/td\u003e \u003ctd class=\"product-th__value\"\u003eYes, via pump curves\u003c\/td\u003e \u003c\/tr\u003e \u003c\/tbody\u003e \u003c\/table\u003e \u003c\/div\u003e \u003cdiv class=\"gema-section\"\u003e \u003ch2\u003eInstallation\u003c\/h2\u003e \u003cp\u003eInstallation takes place within a suitable water-bearing heating system. Before installation, check connection dimensions, pipe routing, mounting points, and hydraulic integration. The heating module and the connection group must be mounted without stress.\u003c\/p\u003e \u003cp\u003eThe circulation pump must be installed with the appropriate pump unions and seals. Pay attention to flow direction, installation position, accessibility, and electrical supply. The pump may only be put into operation after the system section has been filled and vented.\u003c\/p\u003e \u003c\/div\u003e \u003cdiv class=\"gema-section\"\u003e \u003ch2\u003eNotes\u003c\/h2\u003e \u003cp\u003eThe connection package does not replace project-specific system planning. Operating pressure, expansion vessel, safety valve, blow-off line, pump setting, and electrical protective measures must be coordinated with the specific system.\u003c\/p\u003e \u003cp\u003eAfter installation and initial heating, all threaded, pump, and valve connections should be checked for leaks. Changes to pump settings, shut-off positions, or system pressure should only be made after professional inspection.\u003c\/p\u003e \u003c\/div\u003e \u003cdiv class=\"gema-section\"\u003e \u003ch2\u003eScope of delivery\u003c\/h2\u003e \u003cul\u003e \u003cli\u003e1 x WITA go.future WGF45625 high-efficiency pump, installation length 180 mm, incl. connection cable 1 m\u003c\/li\u003e \u003cli\u003e2 x screw pipe clamp, galvanized\u003c\/li\u003e \u003cli\u003e2 x stud bolt M10 x 80 mm, galvanized\u003c\/li\u003e \u003cli\u003e2 x universal wall plug without collar, 12 x 71 mm\u003c\/li\u003e \u003cli\u003e1 x boiler fill and drain valve 1\/2\u0026quot;\u003c\/li\u003e \u003cli\u003e2 x ball valve 1\u0026quot;\u003c\/li\u003e \u003cli\u003e1 x pump connection set incl. gaskets 1 1\/2\u0026quot;\u003c\/li\u003e \u003cli\u003e1 x check valve 1\u0026quot;\u003c\/li\u003e \u003cli\u003e1 x automatic air vent 1\/2\u0026quot;\u003c\/li\u003e \u003cli\u003e1 x safety valve 3\/4\u0026quot; - 3 bar\u003c\/li\u003e \u003cli\u003e1 x malleable cast iron elbow 1\u0026quot; IA\u003c\/li\u003e \u003cli\u003e3 x malleable cast iron tee 1\u0026quot;\u003c\/li\u003e \u003cli\u003e5 x malleable cast iron double nipple 1\u0026quot;\u003c\/li\u003e \u003cli\u003e1 x malleable cast iron double nipple 3\/4\u0026quot;\u003c\/li\u003e \u003cli\u003e2 x malleable cast iron reducing nipple 1 1\/4\u0026quot; x 1\u0026quot;\u003c\/li\u003e \u003cli\u003e1 x malleable cast iron reducer 1\u0026quot; x 3\/4\u0026quot;\u003c\/li\u003e \u003cli\u003e2 x malleable cast iron reducer 1\u0026quot; x 1\/2\u0026quot;\u003c\/li\u003e \u003c\/ul\u003e \u003c\/div\u003e","brand":"Gema GmbH","offers":[{"title":"Заглавие по подразбиране","offer_id":53522109235548,"sku":"MDCKAP","price":229.16,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0757\/7796\/6428\/files\/gema-anschlusspaket-fur-heizmodul-durchlauferhitzer-1194365.jpg?v=1770692386","url":"https:\/\/bg.gemashop.de\/en\/products\/gema-anschlusspaket-mdc-module-wita-umwaelzpumpe","provider":"GEMA Shop","version":"1.0","type":"link"}