{"product_id":"pufferspeicher-schoenberg-epsr-200-222-liter-waermetauscher","title":"Schönberg EPSR 200 buffer tank, 222 liters with heat exchanger","description":"\u003cdiv class=\"gema-section\"\u003e \u003ch2\u003eProduct Overview \u0026amp; Application Area\u003c\/h2\u003e \u003cp\u003eThe EPSR 200 buffer tank is an energy buffer tank from Schönberg with an integrated lower smooth-tube heat exchanger. It serves as a heat storage unit in water-based heating systems and can be integrated into heating, solid fuel, solar, and CHP systems if the system design is suitable.\u003c\/p\u003e \u003cp\u003eWith its compact storage design, the EPSR 200 is particularly suitable for technical plant areas where heat needs to be temporarily stored, hydraulically decoupled, or introduced into the system via a lower heat exchanger.\u003c\/p\u003e \u003c\/div\u003e \u003cdiv class=\"gema-section\"\u003e \u003ch2\u003eTechnology \u0026amp; Equipment\u003c\/h2\u003e \u003cp\u003eThe storage tank is made of quality steel S235JRG2, is raw on the inside, primed on the outside, and stands on a base ring. A permanently welded smooth-tube heat exchanger is integrated in the lower storage area and can be used for system-side heat transfer.\u003c\/p\u003e \u003cp\u003eThe threaded connections are arranged for easily accessible installation. The tank features charging and discharging connections, sensor and controller connections, an upper vent, and designated connections for electric heating cartridges in the middle and bottom of the tank.\u003c\/p\u003e \u003c\/div\u003e \u003cdiv class=\"gema-section\"\u003e \u003ch2\u003eEveryday Benefits\u003c\/h2\u003e \u003cp\u003eThe EPSR 200 supports more even heat storage in the heating system and can buffer load peaks between the heat generator and the heating circuit. The removable STS-EPS insulation makes installation easier, as the tank can be brought to the installation site without the insulation jacket first.\u003c\/p\u003e \u003cp\u003eThe sensor connections allow the tank to be integrated into a suitable control logic for the entire system. The designated ports for electric heating cartridges provide additional flexibility in system planning.\u003c\/p\u003e \u003c\/div\u003e \u003cdiv class=\"gema-section\"\u003e \u003ch2\u003eSystem Integration \u0026amp; Compatibility\u003c\/h2\u003e \u003cp\u003eThe EPSR 200 is designed for water-based heating systems and can be used as a buffer tank in conjunction with heat generators, heating circuits, and suitable control components. The lower smooth-tube heat exchanger allows for the integration of solar or heating circuits, provided that the hydraulics and control are planned accordingly.\u003c\/p\u003e \u003cp\u003eFor safe operation, the safety valve, expansion vessel, venting, sensor positions, and hydraulic connection logic must be professionally coordinated with the entire system.\u003c\/p\u003e \u003c\/div\u003e \u003cstyle\u003e .product-th{margin-top:2rem}.product-th h2{margin:0 0 1rem}.product-th__table{width:100%;border-collapse:separate;border-spacing:0}.product-th__table td{padding:.95rem 1rem;vertical-align:top}.product-th__label{font-weight:700;width:38%;color:#213670}.product-th__value{color:#1f2937}.product-th__table tr:nth-child(odd) td{background:#f4f7fb}.product-th__table tr:nth-child(even) td{background:#fafbfd} \u003c\/style\u003e \u003cdiv class=\"product-th\"\u003e \u003ch2\u003eTechnical data at a glance\u003c\/h2\u003e \u003cp\u003eThe key technical core data of the Schönberg EPSR 200 for planning, comparison, and integration in the heating system.\u003c\/p\u003e \u003ctable class=\"product-th__table\"\u003e \u003ctbody\u003e \u003ctr\u003e \u003ctd class=\"product-th__label\"\u003eStorage type\u003c\/td\u003e \u003ctd class=\"product-th__value\"\u003eBuffer tank\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd class=\"product-th__label\"\u003eStorage volume\u003c\/td\u003e \u003ctd class=\"product-th__value\"\u003e222 l\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd class=\"product-th__label\"\u003eNumber of heat exchangers\u003c\/td\u003e \u003ctd class=\"product-th__value\"\u003e1\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd class=\"product-th__label\"\u003eInsulation\u003c\/td\u003e \u003ctd class=\"product-th__value\"\u003e100 mm STS EPS or 130 mm STS EPS\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd class=\"product-th__label\"\u003eMax. operating pressure of tank\u003c\/td\u003e \u003ctd class=\"product-th__value\"\u003e5 bar\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd class=\"product-th__label\"\u003eMax. temperature\u003c\/td\u003e \u003ctd class=\"product-th__value\"\u003e95 °C\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd class=\"product-th__label\"\u003eStorage tank material\u003c\/td\u003e \u003ctd class=\"product-th__value\"\u003eQuality steel S235JRG2\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd class=\"product-th__label\"\u003eWeight without insulation\u003c\/td\u003e \u003ctd class=\"product-th__value\"\u003e75 kg\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd class=\"product-th__label\"\u003eHeight with insulation\u003c\/td\u003e \u003ctd class=\"product-th__value\"\u003e940 mm\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd class=\"product-th__label\"\u003eWidth \/ depth without insulation\u003c\/td\u003e \u003ctd class=\"product-th__value\"\u003e600 mm \/ 600 mm\u003c\/td\u003e \u003c\/tr\u003e \u003c\/tbody\u003e \u003c\/table\u003e \u003c\/div\u003e \u003cdiv class=\"gema-section\"\u003e \u003ch2\u003eInstallation\u003c\/h2\u003e \u003cp\u003eThe storage tank is placed vertically on a load-bearing, level surface. Before installation, check the transport route, door widths, ceiling height, tilting dimension, and installation clearance.\u003c\/p\u003e \u003cp\u003eThe hydraulic connection, installation of safety devices, sensor positioning, and any electrical connection of accessories must be carried out by qualified specialists in accordance with applicable engineering standards.\u003c\/p\u003e \u003c\/div\u003e \u003cdiv class=\"gema-section\"\u003e \u003ch2\u003eNotes\u003c\/h2\u003e \u003cp\u003eOperating pressure and operating temperature must not be exceeded. Before commissioning, check connections, venting, safety group, expansion vessel, and system tightness.\u003c\/p\u003e \u003cp\u003eElectric heating elements may only be installed in the designated connections. Electrical installation and testing must be performed by a qualified electrician.\u003c\/p\u003e \u003c\/div\u003e \u003cdiv class=\"gema-section\"\u003e \u003ch2\u003eScope of delivery\u003c\/h2\u003e \u003cul\u003e \u003cli\u003eSchönberg EPSR 200 buffer tank with lower smooth-tube heat exchanger\u003c\/li\u003e \u003c\/ul\u003e \u003c\/div\u003e","brand":"Schönberg","offers":[{"title":"100 mm","offer_id":58168352342364,"sku":"EPSR200+EEKC","price":345.26,"currency_code":"EUR","in_stock":true},{"title":"130 mm","offer_id":58168352473436,"sku":"EPSR200+EEKB","price":443.04,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0757\/7796\/6428\/files\/EPSR.png?v=1782825455","url":"https:\/\/bg.gemashop.de\/en\/products\/buferen-sd-schoenberg-epsr-200-222-litra-toploobmennik","provider":"GEMA Shop","version":"1.0","type":"link"}